C4.4
Key Specifications
Minimum rated power
36,0R ekW (45 kVA)
Maximum rated power
99,0 ekW (123 kVA)
Frequency
50 Hz or 60 Hz
The Cat® C4.4 marine diesel generator set has three-phase 50 Hertz ratings of 38.0, 51.5 and 69.0 ekW with heat exchanger cooling and 36.0, 49.0 and 65.0 ekW with radiator cooling and meets EU CCNR2 emission standards.
The C4.4 motor also offers three-phase ratings of 60 Hertz at 44.0, 58.5, 76.0 and 99.0 ekW with heat exchanger cooling and 42.0, 56.0, 72.0 and 95.0 ekW with radiator cooling. It is available in 12 or 24 V versions and in open or closed generator set forms.
One of its peculiarities is single-sided maintenance which improves and facilitates ease of maintenance, while also reducing overall ownership and operating costs. It is ideal for a wide range of commercial and recreational applications also thanks to its compact shape. These ratings also have Marine Classification Society approved setups.
Why Choosing It
Economic
Among the main advantages of the model are the reduction of management and operating costs, which allow a competitive price, as well as long-lasting construction and extended maintenance intervals.
Simple installation
Thanks to plug and play remote instrument panels, the model is simple to install.
Ecological
The model features low emissions, low noise and vibration levels; 60 Hz complies with EPA Tier 2 regulations, 50 Hz complies with EU 97/68EC Stage II regulations
Safe
Security is the basis of the C4.4 model. It presents:
- Automatic stop for excessive speed
- high fresh water temperature
- low engine oil pressure
- high exhaust gas temperature (if fitted with a wet exhaust system).
Flexible
Available as an open genset or with a soundproof cover and with radiator, heat exchanger or keel cooling options.
Exceptional power quality
Its power quality is exceptional, which makes it suitable and particularly suitable for sophisticated on-board equipment (computers, etc.)
Single power source for propulsion and generator sets
Reduced maintenance and stay costs in the port
Technical Features
TECHNICAL CHARACTERISTICS OF THE GENERATING SET
Minimum rated power | 36,0R ekW (45 kVA) |
Maximum rated power | 99,0 ekW (123 kVA) |
Frequency | 50 Hz or 60 Hz |
Speed | 1.500 o 1.800 rpm |
Emissions/Fuel Strategy | EPA Tier 2 (60 Hz), EU 97/68EC Stage II (50 Hz) |
TECHNICAL SPECIFICATIONS OF THE ENGINE
Engine model | Diesel engine model, 4-stroke and 4-cylinder in line |
Aspiration | NA, T, TA |
Bore | 105 mm |
Stroke | 127 mm |
Displacement | 4.4 l |
Regulator type | Electronic |
DIMENSIONS OF THE GENERATING SET
Length | 1750 mm |
Width | 1215 mm |
Height | 1000 mm |
Weight | 805 kg (1.775 lb) – 1.015 kg (2.338 lb) |
TECHNICAL CHARACTERISTICS OF THE GENERATOR
Excitation | Separate excitation from auxiliary windings to provide 300% short circuit current for up to 10 seconds |
Step | 2/3 |
Number of conductors | 12 reconnectable conductors |
Insulation | Class H |
IP rating | Water protection IP23 (IP44 available for some models, for information contact the dealer) |
Voltage regulator | Solid state voltage regulator with integrated potentiometer for voltage regulation |
Standard Equipment
The engine includes standard equipment, already included in the purchase package. They are:
AIR INTAKE SYSTEM
- Air filter, activated carbon with single element, maintenance indicator and rain cover
- Dry insulated turbocharger (DIT and DITA models only)
- Cold start system with glow plugs
COOLING SYSTEM
- Units with cupro-nickel shell and tube heat exchanger (sized for 50°C ambient air and 32°C seawater) or with keel cooling (sized for 50°C ambient air)
- Deaeration expansion tank
- Plate type engine oil cooler
- Gear driven centrifugal jacket water pump
- Self-priming gear-driven sea water pump
- Caterpillar Extended Life Coolant (Heat Exchanger Cooling Unit)
EXHAUST SYSTEM
- Dry insulated turbocharger
- Water-cooled exhaust manifolds
FUEL SYSTEM
- Water Separator/Primary Fuel Filter with NPT and BSP Connectors (Supplied Separately)
- Secondary fuel filter (SX)
- Electric fuel priming pump
- Excitation stop solenoid for starting
GENERATOR
- 12 reconnectable conductors
- All three-phase models
- Without brushes
- Separate excitation from auxiliary windings to provide 300% short circuit current for up to 10 seconds
- Step 2/3
- Wide voltage band
- IP23 water protection
- Solid state voltage regulator with integrated potentiometer for voltage regulation
- Class H insulation
- Connection poles
LUBRICATION SYSTEM
- Lubricating oil
- Oil filter (SX)
- Dipstick (LH)
- Vapor elimination (closed system)
SUPPORT SYSTEM
- Steel base frame with gudgeon
- Anti-vibration mounts
STARTING/CHARGING SYSTEM
- Electrical grounding system isolated from the negative pole
GENERAL INFORMATIONS
- One-sided maintenance (LH)
- Keel-cooled generator sets do not include keel coolers
Equipment on Demand
Upon request, the following equipment can be added to the engine:
ROOM HEATER KIT
- 240V AC, 120V AC
Only logged in customers who have purchased this product may leave a review.