C32 ACERT Tier 3
Key Specifications
Minimum rated power
730 ekW (913 kVA)
Maximum rated power
940 ekW (1.175 kVA)
Frequency
60 Hz
Among the main features of the C32 Acert generator sets is the after-cooling system with SCAC, separate circuit (Separate Circuit After-Cooling), available for all configurations.
This system allows for less corrosion of the aftercooler through which no sea water circulates.
Thanks to the C32 ACERT generator sets and their features you will be able to reduce ownership and operating costs to a minimum. Engines rated to EPA Tier 3, IMO II, EU Stage IIIA standards are available with heat exchanger (allows optional forward mounting of seawater pump) or keel cooling.
Contact us for more info.
Technical Features
TECHNICAL CHARACTERISTICS OF THE GENERATING SET
Minimum rated power | 730 ekW (913 kVA) |
Maximum rated power | 940 ekW (1.175 kVA) |
Frequency | 60 Hz |
Speed | 1.800 rpm |
Emissions/Fuel Strategy | EPA Tier III |
TECHNICAL SPECIFICATIONS OF THE ENGINE
Aspiration | Intake with turbocharger and aftercooler |
Bore | 145 mm |
Stroke | 162 mm |
Displacement | 32.1 l |
Regulator type | Electronic |
Fuel system | MEUI |
Engine model | 4-stroke diesel configuration, V 12 |
DIMENSIONS OF THE GENERATING SET
Width | 1528 mm |
Height | 1667 mm |
Weight (estimated) | 7131 kg |
Length | 162,8 in / 4.271 mm (minimum), 175,3 in / 4.452 mm (maximum) |
TECHNICAL CHARACTERISTICS OF THE GENERATOR
Excitation | Excitation Permanent magnet |
Number of poles | 4 |
Number of bearings | 2 roller bearings |
Number of conductors | 6 |
Insulation | Class H |
IP rating | 23 |
Voltage regulator | CDVR |
Standard Equipment
The engine includes standard equipment, already included in the purchase package. They are:
AIR INTAKE SYSTEM
- SCAC (Separate circuit after-cooled)
- Turbocharger, cooled by jacket water
- Turbocharger inlet, straight fitting OD of 152 mm (6 in)
CONTROL SYSTEM
- If an EMCP panel or MGCP option is not selected as optional equipment, start/stop controls must be provided by the customer.
- Electronic diagnostics and fault recording
- Motor protection mode for extended use
- Electronic control of the air/fuel ratio
COOLING SYSTEM
- Separate Circuit After-Cooling (SCAC) system for HEX (Heat Exchanged) and keel cooled engines
- Shell & Tube SCAC and Jacket Water (JW) heat exchangers for HEX cooled engines
- SCAC pump, gear driven
- Jacket water pump, gear driven
- Gear-driven seawater pump, with bronze impeller, for HEX-cooled engines only
- HEX water jacket with sea water pump – Connections: I.D. 76.2 mm (3 in) standard
- ANSI 4-bolt flange connection
- HEX jacket water without seawater pump – Connection: 2.5″ hose barb (inlet), 4-bolt ANSI flange (outlet) with I.D. 76.2 mm (3 in) standard
- Keel – Connections: Standard 4-bolt ANSI flange connection with I.D. 76.2 mm (3 in)
- SCAC and JW bypass tanks to maintain correct pump inlet pressures
EXHAUST SYSTEM
- Water-cooled exhaust manifold and turbocharger
- 130 mm (5.12 in) diameter 4-bolt flanged outlet
FLYWHEELS AND RELATED HOUSINGS
- Flywheel housing, SAE No. 0
- Flywheel, 18 inch, 136 teeth
- Rotation according to SAE standards
FUEL SYSTEM
- Double fuel filters, screwed on, serviced right
- Fuel Connection Size: Supply JIC 37 degrees -10 (7/8-14), Return JIC 37 degrees -8 (3/4-16)
- Plate fuel cooler installed downstream of the aftercooler bypass tank
- Fuel delivery pump, gear driven
- Manual fuel priming pump
GENERATORS AND RELATED ACCESSORIES
- Wrapped form SR5
- 2 roller bearings
- Excitation of the permanent magnet
- 4 poles, 6 conductors, Star series connected
- Caterpillar Digital Voltage Regulator (CDVR)
- Class H marine insulation, Class F temperature rise
- Surface mount 3-wire platinum (PT100) RTD, 2 for each phase on the stator and one on each support pad
- Anti-condensation space heaters (2 elements – 240 V AC, 1,000 W)
- IP23 protection suitable for use with fixed water-based local application fire fighting systems (FWBLAFFS, Fixed Water Based Local Application Fire Fighting Systems)
- System IV insulation for protection in extreme environmental conditions
LUBRICATION SYSTEM
- Simplified oil filters, DX maintenance
- Deep oil pan
- RH Service Oil Filler Port Locations
- Dipstick with RH maintenance
- Oil pump, gear driven
SUPPORT SYSTEM
- C-channel shaped guides, height 300 mm (11.81 in)
- Six combined rubber/coil spring insulators
- for installation under the base of the kit, supplied separately
GENERAL INFORMATIONS
- Front shock absorber protection
- Common electrical connection point on HEX and keel cooled engines
Equipment on Demand
Upon request, the following equipment can be added to the engine:
ALLARME E PROTEZIONE
- Pannelli a distanza
- Controller MCS
- Modulo analizzatore di potenza
- Sensori di livello dell’olio, temperatura dei gas di scarico, pressione aria di avviamento, pressione scambiatore di calore
EXHAUST SYSTEM
- Dry elbows
- Flexible fitting
- Flange
- Silencer
- Silencer spark arrester
- Tappo parapioggia
AIR INTAKE SYSTEM
- Air intake filter
- Ventilazione del basamento chiuso
- Air intake adapter
CHARGING SYSTEM
- Caricabatterie, alternatori di carica
CONTROL SYSTEM
- Accessorio di ripartizione del carico
FUEL SYSTEM
- Water separator
LUBRICATION SYSTEM
- Doppi filtri dell’olio, pompa di estrazione
PROTECTION SYSTEM
- Fuel and oil protection
STARTING SYSTEM
- Electric starters – single 24V
- Air starter motor
- Dual starters (electric and air)
- Air starter accessories
- Starting aids – JW heaters
- Battery packs – 24 V – dry
Only logged in customers who have purchased this product may leave a review.